Magnetic Resonance - Technology Information Portal Welcome to MRI Technology
Info
  Sheets

Out-
      side
 



 
 'MRI Safety' 
SEARCH FOR    
 
  2 3 5 A B C D E F G H I J K L M N O P Q R S T U V W X Y Z
Result : Searchterm 'MRI Safety' found in 2 terms [] and 40 definitions []
previous     16 - 20 (of 42)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
Searchterm 'MRI Safety' was also found in the following services: 
spacer
News  (32)  Resources  (30)  Forum  (2)  
 
Cardiovascular ImagingMRI Resource Directory:
 - Cardiovascular Imaging -
 
Cardiovascular MR imaging includes the complete anatomical display of the heart with CINE imaging of all phases of the heartbeat. Ultrafast techniques make breath hold three-dimensional coverage of the heart in different cardiac axes feasible. Cardiac MRI provides reliable anatomical and functional assessment of the heart and evaluation of myocardial viability and coronary artery disease by a noninvasive diagnostic imaging technique.
Cardiovascular MRI offers potential advantages over radioisotopic techniques because it provides superior spatial resolution, does not use ionizing radiation, has no imaging orientations constraints and contrast resolution better than echocardiography. It also offers direct visualization and characterization of atherosclerotic plaques and diseased vessel walls and surrounding tissues in cardiovascular research.
MRI perfusion approaches measure the alteration of regional myocardial magnetic properties after the intravenous injection of contrast agents and assess the extent of injury after a myocardial infarction and the presence of myocardial viability with a technique based on late enhancement. Extracellular MRI contrast agents, like Gd-DTPA, accumulate only in irreversibly damaged myocardium after a time period of at least 10 minutes.
This type of patients may also have an implanted cardiac stent, bypass or a cardiac pacemaker and special caution should be observed on the MRI safety and the contraindications. While a number of coronary stents have been tested and reported to be MRI compatible, coronary stents must be assessed on an individual basis, with the medical team weighing the risks and benefits of the MRI procedure.

Cardiac MRI overview:
•
Myocardial perfusion imaging and viability
•
Calculation of ventricular volume, myocardial mass and wall thickness
•
Functional parameters
•
Description of a stenosis or aneurysma
•
Anatomical display of the heart, vessels and the surrounding tissue

Cardiovascular MRI has become one of the most effective noninvasive imaging techniques for almost all groups of heart and vascular disease.
 
Images, Movies, Sliders:
 Angulation of Cardiac Planes Cine Images of Septal Infarct  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Left Circumflex Ischemia First-pass Contrast Enhancement  Open this link in a new window
      

Courtesy of  Robert R. Edelman

 Delayed Myocardial Contrast Enhancement from Infarct  Open this link in a new window
 
spacer

• View the NEWS results for 'Cardiovascular Imaging' (6).Open this link in a new window.
 
Further Reading:
  Basics:
Cardiac MRI - Technical Aspects Primer
Wednesday, 7 August 2002
Coronary Artery Disease: Combined Stress MR Imaging Protocol-One-Stop Evaluation of Myocardial Perfusion and Function1
   by radiology.rsnajnls.org    
A Guide To Cardiac Imaging
   by www.simplyphysics.com    
  News & More:
New Imaging Technique Reveals Different Heart Motions by Age, Gender
Thursday, 10 December 2009   by www.sciencedaily.com    
MRI Resources 
Contrast Agents - Research Labs - Liver Imaging - Stimulator pool - Bioinformatics - MR Myelography
 
ClipsMRI Resource Directory:
 - Safety -
 
mri safety guidance
MRI Safety Guidance
Cerebral (aneurysm) clips are at first contraindicated for MRI examinations unless specifically approved.
Other type of clips: Examinations may be done a few weeks after an operation. Movement of clips or staples placed in a body cavity can present a hazard, but this is often reduced due to the formation of fibrosis around the clips.
spacer

• View the DATABASE results for 'Clips' (6).Open this link in a new window

MRI Resources 
Implant and Prosthesis - Mobile MRI - MRCP - PACS - Functional MRI - Crystallography
 
Cochlear ImplantMRI Resource Directory:
 - Safety -
 
mri safety guidance
MRI Safety Guidance
Not necessarily a contraindication, but the examination may damage or impair it. Interference in electronic cochlear implants and ferromagnetic mechanical stapedial replacements has been reported.
spacer

• View the DATABASE results for 'Cochlear Implant' (2).Open this link in a new window

 
Further Reading:
  Basics:
Pain, magnet displacement in MRI in patients with cochlear implants
Thursday, 20 November 2014   by medicalxpress.com    
Pediatric and Adult Cochlear Implantation1
2003   by radiographics.rsnajnls.org    
  News & More:
FDA Approves MED-EL's SYNCHRONY Cochlear Implant
Friday, 23 January 2015   by www.businesswire.com    
Hazards: Scanners Can Damage Hearing Implants
Wednesday, 10 December 2008   by www.nytimes.com    
Searchterm 'MRI Safety' was also found in the following services: 
spacer
News  (32)  Resources  (30)  Forum  (2)  
 
Credit CardsMRI Resource Directory:
 - Safety -
 
mri safety guidance
MRI Safety Guidance
The magnetic memory of credit and similar cards, as well as magnetic devices such as tapes, will be erased by MR magnets.
spacer

• View the DATABASE results for 'Credit Cards' (2).Open this link in a new window

MRI Resources 
Mobile MRI Rental - Devices - Coils - Manufacturers - Mobile MRI - MR Guided Interventions
 
Foreign BodiesMRI Resource Directory:
 - MRI Accidents -
 
mri safety guidance
MRI Safety Guidance
Occult incorporated ferromagnetic foreign bodies are dangerous, in particular those close to the eyes. The patient's history may help because many patients do not remember such accidents. In case of doubt, X-rays should be taken prior to MR imaging.
spacer

• View the DATABASE results for 'Foreign Bodies' (3).Open this link in a new window

MRI Resources 
Shoulder MRI - Contrast Enhanced MRI - Supplies - Universities - Nerve Stimulator - Jobs pool
 
previous      16 - 20 (of 42)     next
Result Pages : [1]  [2 3 4 5 6 7 8 9]
 Random Page
 
Share This Page
FacebookTwitterLinkedIn

MR-TIP    
Community   
User
Pass
Forgot your UserID/Password ?    



Next big thing in MRI will be :
AI 
remote operator 
personalized protocols 
helium-free 
molecular MRI 
portable MRI 

Look
      Ups





MR-TIP.com uses cookies! By browsing MR-TIP.com, you agree to our use of cookies.

Magnetic Resonance - Technology Information Portal
Member of SoftWays' Medical Imaging Group - MR-TIP • Radiology-TIP • Medical-Ultrasound-Imaging • 
Copyright © 2003 - 2024 SoftWays. All rights reserved. [ 1 May 2024]
Terms of Use | Privacy Policy | Advertising
 [last update: 2024-02-26 03:41:00]